[CS2-05]CALCULATION OF SHIELD TUNNEL LINING’S CROSS-SECTIONAL FORCES USING JAPANESE CONVENTIONAL METHOD AND MUIR WOOD-CURTIS SOLUTION
*Brilleon Agusnatan1, Pongwit Rungbanaphan1, Takeshi SUGIURA1(1. Shimizu Corporation)
Keywords:
Shield Tunnel Lining,Calculation Method,A.M. Muir Wood,The Japanese Conventional Method
This paper presents the comparison of cross-sectional forces between Japanese conventional method (mainly applied in Japan) and Muir Wood-Curtis Solution (mainly applied in Europe) and their suitability to be applied under different ground conditions, groundwater level, depths and tunnel sizes are discussed.