Presentation Information
[1B03]Study on Improvement of Safety for Accident Conditions in Spent Fuel Pool(15)CFD analysis on Loss of Cooling and Loss of Coolant Accidents in SFP
*Kensuke Kobayashi1, Toru Kanazawa1, Masayuki Tojo1, Daisuke Goto1, Yoshiyuki Nemoto2, Yoshiyuki Kaji2 (1. GNF-J, 2. JAEA)
Keywords:
SFP,LOCA,CFD,Natural Convection,Fuel Loading Pattern,Fuel Temperature,Porous Body Approximation,STAR-CCM+
About the condition of loss of coolant in the SFP, the macroscopic flow condition and the temparature distribution in the reactor building are evaluated through the CFD analysis overall the oparating floor at the reactor building. Also, the spent fuels aproximating the porous body are loading into SFP, the fuel temparature distribution depend on the fuel loading pattern are evaluated.