Presentation Information
[1B16]Development of the evaluation method for the advanced level 2 probabilistic risk assessment(4)Development of filtered containment venting system performance evaluation tool
*Taizo Kanai1, Masahiro Furuya1, Koichi Nakamura1, Hiroshi Endo1, Yoshihisa Nishi1 (1. CRIEPI)
Keywords:
Filtered containment venting system,Level 2 PRA,Source term,Severe accident
A filtered containment venting system (FCVS) reduces containment pressure and the radioactive release into the environment during a severe nuclear power plant accident. The FCVS removes radioactive materials via various process and these performance varies from moment to moment. CRIEPI has developed a FCVS simulator which evaluate aerosol, iodine and organic iodine removal performance by the FCVS (decontamination factor: DF) and the FCVS system behavior.