[1A07]Evaluation of characteristic of natural circulation flow on isolation condenser in the presence of non-condensable gas
*Tetsuya Takada1, Yasunori Yamamoto1, Kosuke Ono1(1. Hokkaido Univ.)
Keywords:
Isolation condenser,Non-condensable gas,Natural circulation flow,High pressure steam
High pressure experiments simulating isolation condenser were conducted, where non-condensable gas, helium was injected into the experimental loop. Our results indicated that pressure under quasi-steady state at constant heat input increased with increasing injected helium, which was mainly caused by the increment of pressure loss at the downcomer.