Presentation Information

[19p-B6-17]Charge behaviors in compressed Alq3-based organic MIS diodes observed by displacement current measurement

〇(M1)Aoi Ito1, Takaaki Suzuki1, Yuya Tanaka1 (1.Gunma Univ.)
PDF DownloadDownload PDF

Keywords:

displacement current measurement,charge transport,capacitance

We constructed a measurement system that is capacitance (C)-voltage measurement, called displacement current method (DCM) for organic MIS device made of tris-(8-hydroxyquinolinato)aluminum (Alq3) under pressure and observed charge injection and accumulation processes. When the pressure applied to the device was increased from 159 kPa to 1.59 MPa, not only the thickness of the device film was decreased, but also the response speed of charge was decreased.

Comment