Presentation Information

[2L18]Estimation of contamination infiltrated through building concrete(2) Comparison of predicted data with actual measurements

*Yuki Sasaki1, Kazuyuki Torii1, Hitoshi Nakashima1, Norikazu Kinoshita1, Hirofumi Noguchi2, Hikaru Takada2 (1. Shimizu, 2. JAPC)

Keywords:

Infiltrated contamination,Gamma camera,Surface dose,Actual measurements,Measurement efficiency

To verify the applicability of the contamination penetration estimation method described in the previous paper (1), we compared the estimated results and the actual measured values. The estimated values generally aligned with the measured values obtained from core boring, indicating that Kinoshita et al.'s infiltration model can be applied to contamination penetration over extended periods of liquid contact. Accurately estimating the depth of contamination can lead to increased efficiency in measurement and decontamination operations.

Comment

To browse or post comments, you must log in.Log in