[TuD4-06]100 GHz O- to L-Band Balanced Photodetector Module
〇Jonas Gläsel1, Hendrik Boerma1, Johannes Fabian Eppli1, Christina Wunsch1, Felix Ganzer1, Patrick Runge1, Martin Schell1,2 (1. Fraunhofer HHI (Germany), 2. Technische Univ. Berlin (Germany))
We present a balanced photodetector module with a responsivity of 0.35 A/W at 1310 nm and 0.4 A/W at 1550 nm with a −3 dB-bandwidth of 108 GHz. The device outperforms current state-of-the-art modules regarding RF bandwidth and expands the operation range from the long-haul C- & L-band down to the O-band for short reach QAM transmission in data centers.