Presentation Information
[22a-D903-13]Measurement of electron injection barriers in OS/Au (OS=phthalocyanine and pentacene) using accumulated charge measurement
Takeshi Oda1, 〇Hiroyuki Tajima1, Tomofumi Kadoya2 (1.Univ. Hyogo, 2.Konan Univ.)
Keywords:
organic semiconductor,accumulated charge measurement,charge injection barrier
Accumulated charge measurement is an experimental technique employed for studying the charge injection and extraction process in MIOM capacitor. In this presentation, we report the measurement of electron injection barriers in Au/OS (OS = H2Pc or pentacene) using this technique.