Presentation Information
[16p-PB3-5]Temperature measurement by means of pulsed optically detected magnetic resonance with NV centers in nanodiamonds
〇Keigo Hayashi1, Shuntaro Usui1, Ken Sekiguchi1, Ryota Nomura1, Takashi Tanii1 (1.Waseda Univ.)
Keywords:
nanodiamonds,Nitrogen-Vacancy Center,Temperature measurement
This study evaluated the reproducibility of deta results from Ramsey measurements on the same nanodiamond when temperature is changed repeatedly using a heater. The reproducibility of the temperature response of the same nanodiamond was evaluated while referencing a temperature obtained using a platinum resistance thermometer.