Presentation Information

[17p-W9_325-6]Investigation of the Effects of Partial Shading on the Measurement of Heat Transfer Coefficients of Photovoltaic Modules

〇Kenji KAMIDE1, Katsuto TANAHASHI1 (1.AIST)

Keywords:

photovoltaics,heat transfer coefficient,partial shading

We are developing a thermal balance model for photovoltaic (PV) modules under actual installation conditions. As part of this work, we are developing a method to determine the effective convective heat transfer coefficient, h_eff (W m^-2 K^-1), which is a key model parameter, based on field measurement data from outdoor-installed PV modules. In such measurements, partial shading can be a source of error due to discrepancies between the solar irradiance measured by a pyranometer installed at a specific location and the actual irradiance incident on the PV module, and therefore requires careful consideration. In this study, measurements were conducted under installation conditions where partial shading occurred.

Comment

To browse or post comments, you must log in.Log in