Presentation Information
[C-12-02]Digital Trimming of Clock Generator for Third-order CIFF Delta-Sigma Modulator for isolated ADC
〇Jun Tomisawa1, Shota Morisaki1 (1. Mitsubishi Electric Corp.)
Keywords:
Delta Sigma Modulator,ADC,Digital trimming,Automatic measurement,CIFF
Isolated ADC needs for integration into power modules to output current and temperature information as isolated digital signals. As a building block for the isolated ADC, a third-order CIFF ΔΣ modulator has been prototyped in X-FAB’s 0.35-μm process (XA035). An automatic measurement system was developed for the fabricated chip, and measurements were performed using a digital trimming clock generator. With the digital trim enabled, the measured chip achieved a maximum SNR of 96.9 dB, confirming an improvement over the untrimmed case.