[2N01]Enhancement of Analysis Method for Important Phenomena of Severe Accident at Reprocessing Plant(D-12) Development of Hygroscopic Aerosol Calculation Model for Two Component Solvent

*Daisuke Fujiwara1, Hisayuki Kyo1, Kouya Ganaha1, Hiroshi Shirai1, Takashi Kodama2, Yoshikazu Tamauchi2, Naoya Satou2 (1. TEPSYS, 2. JNFL)

Keywords:

Boiling and drying out accident,FATE,Aerosol hygroscopicity,Mason equation,Kelvin effect,Solute-mass effect,Fuchs correction

Hygroscopic aerosol calculation model was developed for boiling and drying out accident analysis code FATE. This model is based on Mason equation, Kelvin effect model, Solute-mass effect model, and Fuchs model, and that was enhanced to treat two component solvent.

Comment