[23a-A306-8]Performance Evaluation of X-ray Imaging Detectors on Spacecraft for Low Energy Bands
〇Daisuke Hatanaka1, Kenjiro Fujimoto1, Junko Hiraga1, Naoki Ogino2, Makoto Arimoto2, Daisuke Yonetoku2, Kensho Sei3, Takanori Sakamoto3 (1.Kwansei Gakuin Univ., 2.Kanazawa Univ., 3.Aoyama Gakuin Univ.)
Keywords:
X-ray,semiconductor detector
We have been developing a focal plane detector for a wide-field X-ray monitor onboard the HiZ-GUNDAM satellite. The mission requires a detection efficiency of more than 50% for X-rays in the 0.4-4.0 keV band, and a fully depleted, back-illuminated pnCCD device was selected as a candidate detector. In this study, we detected emission lines near the lower limit of the mission-required bandwidth using a smaller device than those used onboard satellites, and evaluated the energy dependence of the energy resolution and the the gain linearity.