講演情報

[Structure-07]Evaluation of the Adhesion Performance of an Epoxy-Based Corrosion Inhibitor for Steel Decks bridge Incorporating Thermally Expandable Microcapsules

*Akitaka Kiuchi1, Yatuhiro Ichinose1, Shinya Yokota1, Kazuhiko Minakuchi2, Hiroyuki Noguchi2 (1. KAJIMA ROAD CO.LTD (Japan), 2. NIHON UNIVERSITY (Japan))

キーワード:

steel bridge deck、steel fiber–reinforced concrete pavement、corrosion inhibitor、thermally expandable microcapsules、adhesive tensile strength

Many steel bridge decks have been reported to develop fatigue cracks at the welds between the deck plate and U-ribs, driven by recent increases in traffic volume and the growth in heavy-vehicle traffic. As a countermeasure, a strengthening method has been implemented in which the existing asphalt pavement is removed and replaced with a high-stiffness steel fiber - reinforced concrete pavement. When teel fiber - reinforced concrete pavement is employed for fatigue mitigation, an adhesive is applied to ensure a robust bond between the steel deck and the steel fiber - reinforced concrete. In the steel fiber - reinforced concrete strengthening method for steel bridge decks, a removal technique has been developed-anticipating future maintenance-that mitigates noise during steel fiber-reinforced concrete removal by incorporating thermally expandable microcapsules into the corrosion inhibitor.This study investigates the effect of a corrosion inhibitor incorporating thermally expandable microcapsules on the tensile bond strength of a high- performance epoxy-adhesive.As a result of the investigation, we confirmed that sufficient tensile strength was retained when subjected to environmental stressors expected during the construction period - namely ultraviolet radiation, rainwater, and temperature rise due to direct sunlight. Furthermore, after fatigue loading imposed by a wheel-load running test, sufficient tensile strength was also confirmed.