Presentation Information

[2K13]Study on vitrification plan of high level liquid waste in the TVF(9)Consideration of operating parameters for the new glass melter

*Masaya Tone1, Daiki Shiramizu1, Nanako Katsuoka1, Yusuke Aoyama1, Koshi Miyata1, Shigeki Fukuda1, Hikaru Ohtaka1, Hidekazu Kobayashi1, Akira Kodaka1 (1. JAEA)

Keywords:

TVF,TVF's 3rd glass melter,Vitrification,Operating parameters,LFCM

The replacement of existing 2nd glass melter with the 3rd glass melter is scheduled from 2025 to 2026 in Tokai Vitrification Facility, TVF. The bottom shape of 3rd melter was changed from the square pyramid of 2nd melter to a cone to improve ability to discharge platinum group elements. Therefore, it is necessary to confirm operational parameters appropriate for the 3rd melter with cone shaped bottom. Operational test using non-radioactive simulant of liquid waste was carried out to ensure the appropriate operational parameters that accommodate key control values such as glass temperature.

Comment

To browse or post comments, you must log in.Log in