Presentation Information

[16a-K209-7]Changes in Parameters for Superconducting Digital Circuits over Long Time.

〇Mutsuo Hidaka1, Shuichi Nagasawa1 (1.AIST)

Keywords:

superconducting digital circuit,critical current density,changes over long time

We investigated changes in parameters for superconducting digital circuits over long time by measuring past chips which exists past measurement data. The chips have been kept in room temperature atmosphere up to 15 and half years. Critical current density of Josephson junctions has reduced about 5% with 10 years. We think that the reductions were caused by the same phenomena with annealing.

Comment

To browse or post comments, you must log in.Log in