Session Details

[17a-D62-1~7]2.4 Medical application

Tue. Sep 17, 2024 10:00 AM - 11:45 AM JST
Tue. Sep 17, 2024 1:00 AM - 2:45 AM UTC
D62 (Bandaijima Bldg)
Yusuke Koba(QST), Chang Weishan(Tokyo Metropolitan University)

[17a-D62-1]Identification of 177mLu in 177Lu-oxodotreotide using Compton camera

〇Takahiro Mizoguchi1, Takara Watanabe1, Daisuke Kano2, Ryoji Enomoto1, Hideaki Katagiri3, Mika Kagaya4, Hikari Tsukamoto1, Masaya Fukumoto1, Hiroshi Muraishi1 (1.Kitasato Univ., 2.NCCHE, 3.Ibaraki Univ., 4.NIT, Sendai Col)
Comment()

[17a-D62-2]ML-EM image reconstruction in a rotating omnidirectional Compton camera : Extended radiation source imaging

〇Masaya Fukumoto1, Hiroshi Muraishi1, Ryoji Enomoto1, Hideaki Katagiri2, Mika Kagaya3, Takara Watanabe1, Kazuya Sakaguchi1, Takahiro Mizoguchi1, Hikari Tsukamoto1,4, Daisuke Kano5 (1.Kitasato Univ., 2.Ibaraki Univ., 3.NIT Sendai College, 4.Tokai Univ. Hospital, 5.NCCHE)
Comment()

[17a-D62-3]Development of high-sensitivity Compton camera for Lu-177 radioactive contamination imaging

〇(D)Hikari Tsukamoto1,5, Hiroshi Muraishi1, Ryoji Enomoto1, Hideaki Katagiri2, Mika Kagaya3, Takara Watanabe1, Daisuke Kano4, Takahiro Mizoguchi1, Masaya Fukumoto1, Yusuke Watanabe1 (1.Kitasato Univ., 2.Ibaraki Univ., 3.NIT, Sendai Col., 4.NCCHE, 5.Tokai Univ. Hosp)
Comment()

[17a-D62-4]A preliminary study of the 4D dose distribution estimation using gel dosimeter

〇(DC)Ryosuke Narita1, Masao Gohdo2, Shin-ichiro Hayashi3, Yoshinori Sakurai4 (1.Grad. Sch. Eng., Kyoto Univ., 2.SANKEN, Osaka Univ., 3.Hiroshima Intl Univ., 4.KURNS, Kyoto Univ.)
Comment()

[17a-D62-5]Ex vivo imaging of fatty liver rats using photon-counting CT for evaluation of liver disease

〇(M2)Takahiro Tomoda1, Makoto Arimoto1, Daichi Sato2, Fitri Lucyana1, Yuki Ito1, Minori Oshima1, Yu Furuta1, Hiroki Kawashima1, Satoshi Kobayashi1, Kenichiro Okumura1, Jun Kataoka3, Ryotaro Minagawa3, Shinsuke Terazawa4, Satoshi Shiota4 (1.Kanazawa Univ., 2.Tohoku Univ., 3.Waseda Univ., 4.Proterial Ltd.)
Comment()

[17a-D62-6]Evaluation of Platinum-Based Anticancer Drugs Using Photon-Counting CT with MPPCs

〇(B)Yu Furuta1, Makoto Arimoto1, Takahiro Tomoda1, Fitri Lucyana1, Mirei Oshima1, Yuki Ito1, Hiroki Kawashima1, Satoshi Kobayashi1, Kenichiro Okumura1, Hikaru Onoda2, Kaisei Tanaka2, Tomohiro Tanaka2, Masashi Ueda2, Jun Kataoka3, Ryotaro Minagawa3, Daichi Sato4, Shinsuke Terazawa5, Satoshi Shiota5 (1.Kanazawa Univ., 2.Okayama Univ., 3.Waseda Univ., 4.Tohoku Univ., 5.Proterial Ltd.)
Comment()

[17a-D62-7]Preliminary evaluation of dynamic imaging results of contrast agent sample using a 2-dimensional MPPC-based photon counting CT detector system

〇(M2)Fitri Lucyana1, Makoto Arimoto1, Takahiro Tomoda1, Minori Oshima1, Yu Furuta1, Hiroki Kawashima1, Satoshi Kobayashi1, Kazuhiro Murakami1, Kenichiro Okumura1, Jun Kataoka2, Ryotaro Minagawa2, Daichi Sato3, Shinsuke Terazawa4, Satoshi Shiota4 (1.Kanazawa Univ., 2.Waseda Univ., 3.Tohoku Univ., 4.Proterial Ltd.)
Comment()