Presentation Information

[1B07]Effect of Magnetron Sputtering Conditions on TiZrV Coating Deposited Using a Compact NEG-Coating Device

*Ruau Watanabe1, Yasunori Tanimoto1,2, Jin Xiuguang1,2, Takashi Uchiyama2, Takashi Nogami2, Tohru Honda2 (1. The Graduate University for Advanced Studies, SOKENDAI (Japan), 2. The High Energy Accelerator Research Organization, KEK (Japan))
To realize NEG-coating in vacuum chambers with complex geometries, we have developed a compact flange-mountable magnetron sputtering device using a cylindrical TiZrV-alloy target and a periodically arranged permanent-magnet array. TiZrV films were deposited in a DN63 cross tube under various sputtering conditions to investigate the effects of sputtering-gas flow and magnet arrangement. The deposited films showed fine-grained surface morphology and columnar cross-sectional structure, and the activated NEG-coated duct achieved a base pressure in the 10-10 Pa range without breaking vacuum. A lower sputtering pressure resulted in a smaller thickness difference between two measurement positions than a higher pressure, whereas only a marginal difference was observed between balanced and unbalanced-type magnetron configurations. These results provide useful information for optimizing the coating process using the compact NEG-coating device.