Presentation Information
[1A10]JAEA/FNS Iron Experiment Analyses with JENDL-4.0 and JENDL-5
*Chikara Konno1, Saerom Kwon2 (1. JAEA, 2. QST)
Keywords:
FNS iron experiment,JENDL-4.0,JENDL-5,iron data,DORT
MCNP analyses of the JAEA/FNS iron experiment with the MCNP code for JENDL-5 showed that neutron fluxes above 10 MeV and below 10 keV were different at most by 10% between JENDL-4.0 and JENDL-5. Thus, we investigated the causes with the DORT code. Then it was found that the differences of the neutron fluxes above 10 MeV and below 10 keV were caused by those of the elastic scattering, (n,2n) and (n,np) reaction data in 56Fe and those of the inelastic scattering data in 56Fe and 57Fe between JENDL-4.0 and JENDL-5, respectively.